MULTIBOARD


Waterproofing panel test reports


PROPERTIES TEST RESULTS UNIT TEST METHOD
Compressive Strength 183 kPa EN 826
Apparent Density 38,82 % EN 1604
Dimensional Stability (70 º C) ∆∑l: %0,7
∆∑b: %1,1
∆∑d: %2,6
% EN 1604
Dimensional Stability (-20 ° C) ∆∑l: %0,0
∆∑b %0,0
∆∑d: %0,1
% EN 1604
Water Vapor Permeability Water vapor diffusion strength :87,19 - EN 12086
Thermal Conductivity (Basic) 0,0246 W/(m.K) EN 12667
Thermal Conductivity (Aged) Test süreci devam etmekte W/(m.K) EN 13165 EKC


Incombustibility

TS EN ISO 11925-2 Building materials – fire resistance tests - Ignitability when subjected to direct flame – Section 2: Single-flame source test


Test Metod TS EN ISO 11925 - 2
Flame Application Duration 15s
Conditioning TS EB 13238 Madde 4.3.c
Tested values and Test results
Exposure to flame from surface Vertical Horizontal
Sample no 1 2 3 1 2 3
Combustion on sample No No No No No No
Reaching signals No No No No No No
Combustion filter paper No No No No No No
Observations during test No flaming drops were observed on samples.


TEST METHOD: TS EN 13823 Reaction to fire tests for construction products-Exposure to thermal effect – construction products excluding layers Conditioning: TS EN 13238 Article 4.3.c (23 ± 2) ° C and (50 ± 5) % relative humidity

Tested Values and Test Results
Test Sample No. 1 2 3 Ø  Extended Measurement Uncertainty
Test Date 05.12 05.12 05.12
LFS> Edge No No No No (-)
Fıgra0,2MJ [W/s] 1132,72 1301,70 1596,02 1343,48 270,03
Fıgra0,4 MJ [W/s] 1132,72 1301,70 1596,02 1343,48 270,73
THR600s [m2] 8,19 8,15 7,90 8,08 0,49
SMOGRA [m2/s2] 160,41 172,90 228,37 187,23 41,77
TSP600s[m2] 207,48 158,78 174,22 180,16 28,74
Flaming Drops / Pieces None None None None (-)
Combustion Time (-) (-) (-) (-) (-)
Observations during test: No flaming drops were observed on samples.


Fire Classification Test

Test Method Parameter Test Number Results
Continuous Parameter Average Correct Parameter
TS EN ISO 11925-2

Fs <=150mm

Combustion on Filter Paper

6 (-) Evet
6 (-) No
(-): not applicable

Test Method Parameter Parameter Conformity criteria
TS EN ISO 11925-2

Fs <= 150 mm

Combustion on Filter Paper

Yes Yes(E)
No No(E)


 Tebar Resitance Tests

PDF
Thermal Insulation Panel TS EN 826
Thermal Insulation Panel TS EN 1602
Thermal Insulation Panel Dimensional Stability (-20 Derece) TS EN 1604
Thermal Insulation Panel Dimensional Stability (70 Derece) TS EN 1604
Thermal Insulation Panel Water Vapour Transmission Properties TS EN 12086
Thermal Insulation Panel Conductivity TS EN 12667
About Thermal Insulation Panel Reports


 Fire Tests

PDF
Thermal Insulation Panel TS EN 13165
Thermal Insulation Panel TS EN ISO 11925-2
Thermal Insulation Panel TS EN 13823
Web Tasarım - Acıbadem Medya