TUNNEL APPLICATION DETAILS


MATERIAL SPECIFICATIONS


Multiplan BAT PVC Tunnel Membrane TDS

Producer name and address : MULTİPLAN YALITIM SİSTEMLERİ SAN.TİC.A.Ş G.O.S.B. İhsandede Caddesi No:111/B Gebze/KOCAELİ / TÜRKİYE
Product title: MULTİPLAN BA/T
Description : Homogeneous, Signal Layered PVC Water Insulation Membrane, not complying with bitumen
Related European Standard : TS EN 13967
Mechanic stabilization
Standard Dimensions : Width: 2200 mm
Thickness: 1,5 mm; 2,0 mm


PROPERTIES REQUIRED MIN. VALUE UNIT TEST METHOD
Waterproofing Watertight - TS EN 1928
Static load resistance > 20 kg TS EN 12730
Tensile strength > 15 N/mm2 TS EN 12311-2
Breaking elongation > 250 % TS EN 12311-2
Post-aging waterproofing Watertight - TS EN 1296 VE TS EN 1928
Impact strength > 450 mm TS EN 12691
Tearing strength > 300 N TS EN 12310-1
Reaction to fire E Class - Sınıflandırma TS EN 13501-1
Joint sliding strength > 600 N/50mm TS EN 12317-2
Determination of water vapour transmittance > 18.000 + %30 µ TS EN 1931
Joint peeling strength > 150 N/50mm TS EN 12316-2
Dimensional stability < 2 % TS EN 1107-2
Elasticity in cold < -20 °C TS EN 495-5
Visible defects Flawless - TS EN 1850-2

GEOTEXTILE FELT


Geotextile felt shall be used for protection with minimum 500 gr/m2.


DELIVERY AND STORAGE


PVC membrane shall be packaged appropriately for Geotextile felt rolls not to be damaged, and be loaded horizontal. PVC membrane shall be stored to be protected from contamination, oil, mud, mechanical abrasion, high temperature and other damages.


GUARANTEE


Multiplan BAT PVC membranes are under the factory guarantee for 10 years.